| Description | Line scan camera board by Eureca |
| Articlenumber (Eureca): | 02.29.0029 |
| Origin: | Germany |
| Manufacturer: | Eureca |
| EAN | 0675051081775 |
| Interface | USB |
| Sensor | TCD1304DG |
| Pixel number | 3648 |
| Pixel pitch | 8 µm |
| Pixel height | 200 µm |
| Minimum Exposure Time | 20 µs |
| Supply Current | < 250 mA |
| Supply Voltages | 5 V |
| Size (L×B×H) | 61 × 25 × 12 mm |
| Weight | 25 g |
| Remark | EDU (Educational) Version for Evaluation; available from Q2/2026 |
The EVAL version of our EDU line scan camera is fully functional and ideal for teaching and laboratory environments that want to work with real data early on – with direct contact to the developers and a reduced introductory price.
However, we respond quickly, provide fixes/workarounds, and you are in the front row.
Transparency note: The EVAL version is not currently intended for safety-critical applications!
Professors, research assistants, doctoral students, dedicated teachers & students, and makers who like to be the first to see results.
| Operation mode | 8-bit mode | 12-bit mode |
|---|---|---|
| Digitization Depth | 8 bit | 16 bit left aligned |
| Read out noise (typ. rms) | 300 e− | 50 e− |
| Linear Full Well Capacity | 40 ke− | 40 ke− |
| Full Scale Capacity | 65 ke− | 65 ke− |
| Conversion Gain (typ @ 0.4 FS) | @ 8 Bit: 330±100 e−/LSB | @ 16 Bit: 1.3±0.4 e−/LSB |
| Maximum Frame Rate | 25 fps | 25 fps |
| Integration Start/Stop via USB | ✗ | ✗ |
| Start/Stop via USB Latency | 10 ms | 10 ms |
| External Trigger Input | ✓ | ✓ |
| External Trigger Latency | 20 µs | 20 µs |
| External Trigger Jitter | ±10 µs | ±10 µs |
| External Trigger Latency (debounced) | ✗ | ✗ |
| Isolated external Trigger Input | ✗ | ✗ |
| External Exposure Time Control | ✗ | ✗ |
| Exposure Time Control Latency | ✗ | ✗ |
| Minimum External Exposure Time | ✗ | ✗ |
| Maximum External Exposure Time | ✗ | ✗ |
| Exposure Time Control Latency (debounced) | ✗ | ✗ |
| Minimum External Exposure Time (debounced) | ✗ | ✗ |
| Trigger Output | ✓ | ✓ |
| High Resolution Timestamp: Trigger | ✗ | ✗ |
| GPIO | ✗ | ✗ |
| Enhanced Frame Buffer | ✗ | ✗ |
This module uses the standard version of the TCD1304DG and is therefore suitable for general measuring tasks in the visible spectral range.
Further information, source codes and documentation can be found on our service page!
For orders (also from end customers) please use the link below.
For offers for larger quantities, please contact us by e-mail.
Documents for download:
More pictures of the product:
Changes to the specifications by the manufacturer are possible without prior notice. Please contact us if needed or interested. We also advise you on the suitability of the product for a particular application and provide you with an individual price quote.
Last update: 11.05.2025