Cooling Systems
Peltier Elements
Seebeck Elements
(TEGs)
Heat Conducting and
Isolating Prodcuts
Heat Sinks
Heat Exchanger
Fans
Heat conducting film
Power Supplies
Services
Startseite Optoelectronic Optics Cooling Sockets Consulting Deutsch English Impressum Kontakt AGB

Fans

For improving the performance of heat sinks special fans are used, which are optimized for a permanent operations. Some of the above described heat sinks have already a suitable size for mounting such fans.

Although there are many manufacturers of fans, we have chosen the products by PAPST, since the products of this manufacturer provide an excellent cost/performance ratio and a very long life time.

The most fans are available with Sintec bearing as well as with ball bearing.



Fans Value 60×60×25mm

Type Airflow
[m3/h]
Voltage
range
[VDC]
Sound
[dB(A)]
Sintec
Slide
Bearing
Ball
Bearing
Power-
consump-
tion
[Watt]
Rated
Speed
[min-1]
Tempe-
rature
Range
[°C]
Life Cycle
L10
at 40 °C
[Hours]
612NGHH 56 8-15 (12) 43 x   3 6850 -20-(+70) 60000
612NHH 56 8-15 (12) 43 x 3 6850 -20-(+70) 60000
614NGHH 56 18-26 (24) 43 x 3 6850 -20-(+70) 60000
614NHH 56 18-26 (24) 43 x 3 6850 -20-(+70) 60000


Fans Value 80×80×25mm

Type Airflow
[m3/h]
Voltage
range
[VDC]
Sound
[dB(A)]
Sintec
Slide
Bearing
Ball
Bearing
Power-
consump-
tion
[Watt]
Rated
Speed
[min-1]
Tempe-
rature
Range
[°C]
Life Cycle
L10
at 40 °C
[Hours]
8412NG 69 8-15 (12) 32 x   2 3100 -20-(+70) 70000
8412NH 79 8-13,5 (12) 37 x 2,2 3600 -20-(+70) 70000
8414NG 69 18-28 (24) 32 x 2 3100 -20-(+70) 70000
8414NH 79 18-26 (24) 37 x 2,4 3600 -20-(+70) 70000


Fans Value 92×92×25mm

Type Airflow
[m3/h]
Voltage
range
[VDC]
Sound
[dB(A)]
Sintec
Slide
Bearing
Ball
Bearing
Power-
consump-
tion
[Watt]
Rated
Speed
[min-1]
Tempe-
rature
Range
[°C]
Life Cycle
L10
at 40 °C
[Hours]
3412NGHH 102 8-13,2 (12) 39 x   3,2 3250 -20-(+60) 70000
3414NGHH 102 18-26 (24) 39 x   3,2 3250 -20-(+70)  


Fans Value 119×119×32mm

Type Airflow
[m3/h]
Voltage
range
[VDC]
Sound
[dB(A)]
Sintec
Slide
Bearing
Ball
Bearing
Power-
consump-
tion
[Watt]
Rated
Speed
[min-1]
Tempe-
rature
Range
[°C]
Life Cycle
L10
at 40 °C
[Hours]
4312NGN 166 7-14,5 (12) 43 x 4 3000 -20-(+70) 60000
4312NHH 198 7-14,5 (12) 49 x 6,5 3600 -20-(+60) 57500
4314NGN 166 12-28 (24) 43 x 4,3 3000 -20-(+70) 60000
4314NHH 198 12-28 (24) 49 x 6 3600 -20-(+70) 57500
4318NGN 166 36-56 (48) 43 x 4,1 3000 -20-(+70) 60000


Page updated at: 08/22/2013